text.skipToContent text.skipToNavigation

PARK LATCH SENSOR

2173060
X-Ray
GE HealthCare
Outright
Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • It reduces the manual effort for adjustments
  • It is very small in size
  • Reliable
  • Shielded housings of the lead prevents accidental disconnects

Product Overview

The Park Latch Sensor is used for indicating to the Central Processing Unit (CPU) of the X-ray machine that the X-ray tube arm is in the parked position. When a magnetic field of at least 160 gauss is presented to the surface of the Hall Effect sensor, the output of the sensor sinks the electric current and the output of the board gets activated. The park latch sensor is an assembly that consists of resistors, PNP transistors, semi-conductor diodes, Hall Effect switch, Park sensor, lead wires and other accessories with labels. There are three lead wires connected to the board, one for input supply, one for the grounding and the other for the output. The sensor will be tested with the disk shaped magnet attached to plastic spacer and the magnet can be touched against the sensor with the plastic in between. The voltage across the pull down resistor should be more than 20 VDC when the magnetic field is kept. The sensor is used in the Digital Imaging (DI) machines like AMX 4+, Optima CT660 128-Slice, LOGIQ 500, LightSpeed 5.X Pro 16-Slice, VMX PLUS, Brightspeed 16-Slice, Definium AMX 700, Discovery XR656 G2, Senographe 500T/600T, OEC Stenoscope, Silhouette VR, TelevixMVP, Prodigy Advance Plus Full Size and Infinia II.

  • Additional Features

    • The assembly is easily portable
    • GSPO
    ©2024 GE HealthCare
    GE is a trademark of General Electric Company. Used under trademark license.
    상호명: 지이헬스케어코리아㈜
    대표이사: 김은미
    경기도 성남시 중원구 순환로 214번길 9 / 서울시 중구
    한강대로 415
    사업자 등록번호: 129-81-14880
    Email: my.gehealthcareko@ge.com
    본 사이트는 지이헬스케어코리아㈜가 그 협력사를 대상으로 개설한 부품, 액세서리 및 공급품에 관한 Service Shop으로, 게시물에 대한 무단 복제, 배포는 금지됩니다.