MX135 Venus
5363417 | |
2232785-2 2232785-4 | |
Tubes | |
Brivo CT325 | |
GE HealthCare | 교환 - 반품 결함 |
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer&rsquo | |
승인 번호를 입력하고 장바구니에 품목을 추가하도록 제출하십시오. p>
Please enter approval number
OR
승인 번호를 모르십니까? 800-437-1171로 전화하십시오.
처음 세 개의 프롬프트에 opt 1을 입력하고 시스템 ID를 사용할 수 있도록하십시오.
장바구니에 품목을 추가하고
승인 번호, GE는 배송을 위해 주문을 확인하기 전에 연락을 드릴 것입니다.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
제품 개요
MX135 Venus
High dissipation, high throughput, graphite-backed metal target tube for CT/e, Prospeed Ai & Af, Brivo 315/325/385, SVCT8/16, Optima 640 and NM850/860 systems.
Higher Throughput
• Brazed graphite target design utilizing a patented braze process provides integrity of the graphite to metal bond at temperatures in excess of 1300°C at the target rim.
• Unique insert and housing design facilitate high-heat radiation technology which quickly transfers generated heat at the anode to the ambient environment.
• High-heat transfer technology in conjunction with a 2.0 MHU, 135 mm diameter target provides excellent throughput.
Consistent Imaging
• Cathode and casing designs that enhance the quality of produced X-rays by improving spatial resolution and lowering off focal spot radiation.
• Special treatment of inner glass envelope and space-age coating on the graphite target improve high voltage stability for consistent techniques.
Longer Tube Life
• Innovative preloaded bearing design with heat block mechanisms and three-ball floating rear retainer permits trouble-free rotor operation.
• Patented high-voltage surge protection designed into the tube unit provides exceptional high voltage stability. Additionally, each insert is conditioned to a minimum of 190 kV which provides stability up to the 140 kV tube rating.
• New three-piece casing design improves housing reliability and integrity of the internal housing environment.
동등한 부품 :
아래는 동등한 부품에 대한 자세한 정보입니다. 하이퍼 링크가없는 부품은 참조 용으로 만 나열되며 온라인으로 구입할 수 없습니다.
동등한 부품 | 제품 세부 사항 |
---|---|
2232785-2 | MX135 Venus |
2232785-4 | MX135 Venus Avatar |
반품 및 교환
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer&rsquo