text.skipToContent text.skipToNavigation

Le BT12 Battery Pack

5422172
Ultrasound
LOGIQ e
LOGIQ e
GE HealthCare
되사기
위시리스트에 추가
로그인 하고 장바구니에 추가
로그인 하고 장바구니에 추가
날짜를 선택하세요
두 번째 의견 승인 필요

승인 번호를 입력하고 장바구니에 품목을 추가하도록 제출하십시오.

승인 번호

Please enter approval number

OR

승인 번호를 모르십니까? 800-437-1171로 전화하십시오.
처음 세 개의 프롬프트에 opt 1을 입력하고 시스템 ID를 사용할 수 있도록하십시오.

장바구니에 품목을 추가하고
승인 번호, GE는 배송을 위해 주문을 확인하기 전에 연락을 드릴 것입니다.

두 번째 의견 승인 필요

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


특색

  • High energy density
  • Long lasting
  • Less hazardous to the environment
  • Over charge/discharge/current protection

제품 개요

The LOGIQ e Battery Pack (BT12) is used for the continued operation of any system during power interruptions, which can be achieved by the presence of these batteries. The lithium ion battery provides power when an AC power source is interrupted. Lithium ion batteries last longer than conventional batteries and do not require replacement as often. The lithium ion technology used is significantly less hazardous to the environment than the lithium metal technology used in other similar batteries (such as watch batteries). This particular battery comes with a protection circuit for detecting function of overcharge, over discharge and current over discharge occurrences. The battery pack is capable of continuous charging at 16.8 Volt and a 3000mA maximum current. Charging will be terminated during to minimum current 200mA.The battery pack is capable of continuing discharge at standard discharge current across the entire discharge operating temperature range. Overcharge prevention: 4.30 ± 0.05V/cell (17.4 ± 0.4V/pack) or more (at 25 ℃) with reset when discharged to 4.10 ± 0.1V (16.4 ± 0.4V/pack). Over discharge prevention: 2.30 ± 0.10V/cell (9.2 ± 1.0V/pack) or less (at 25 ℃) with reset when recharged to 2.90 ± 0.15V) 11.60 ± 0.60V/pack) or more. Over current protection: when the battery load current exceeds 8A-12A at 25 ℃ and the over current protector shall trip within 10 sec. When the external load is removed, the charge battery packs the over current protector will reset and the battery pack will operate to requirements specified.

  • 추가 기능

    • Easy maintenance
    • GSPO
    ©2024 GE HealthCare
    GE is a trademark of General Electric Company. Used under trademark license.
    상호명: 지이헬스케어코리아㈜
    대표이사: 김은미
    경기도 성남시 중원구 순환로 214번길 9 / 서울시 중구
    한강대로 415
    사업자 등록번호: 129-81-14880
    Email: my.gehealthcareko@ge.com
    본 사이트는 지이헬스케어코리아㈜가 그 협력사를 대상으로 개설한 부품, 액세서리 및 공급품에 관한 Service Shop으로, 게시물에 대한 무단 복제, 배포는 금지됩니다.