Internal Battery Assy. Pack RSPL Kit
5423275 | |
2378963 2378963-2 FL200027 FL200068 S2378963-3 S2423267 | |
Ultrasound | |
Other Ultrasound | |
GE HealthCare | Outright |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- High energy density
- Long lasting
- Less hazardous to the environment
- Internal safety device
Product Overview
The Internal Battery Assembly is a kit that consists of a battery base, cover, rear rubber, card assembly and battery cell. It is used for ultrasound devices. The Vivid I/Vivid Q ultrasound unit is powered either by its internal battery or by a separate power supply adaptor unit connected to a separate power outlet for any range of 100-240 VAC, 50-60 Hz. The lithium ion battery provides power when an AC power source is interrupted. A battery in the battery bay is standard with Vivid I/Vivid Q. Lithium ion batteries last longer than conventional batteries and do not require replacement as often. It can provide one hour of battery life with a single fully charged battery. The lithium ion technology used is significantly less hazardous to the environment than the lithium metal technology used in any other batteries (such as watch batteries). It has a safety device within it, so it should not be disassembled or altered. Charge and discharge the batteries only when the ambient temperature is between 0° and 65° C (32° and 149° F). Battery insertion or removal should take place only when the system is in "full shutdown" mode. The system has a status icon to display the status of the battery. It is designed to flash special messages for the replacement and re-calibration of the battery. Re-calibration may be required after prolonged usage of the battery, because it’s internal "fuel gauge" (capacity meter) may start to drift. When the battery is out of calibration the system does not read the correct charge stored in the battery. An external battery charger can help to charge the battery in a faster manner. It is recommended to use CH5000V, a standalone desktop smart standard battery charger designed to work with the GE Medical Systems Vivid I smart battery packs. It has the added ability to re-calibrate the fuel gauge on the battery pack and maintain full fuel gauge accuracy throughout the entire life of the battery.
Additional Features
- Can be charged with external adaptor
- GSPO
Equivalent Item(s):
Below is more information on the equivalent item(s). Items without a hyperlink are listed for reference only and are not available for purchase online.
Equivalent Item(s) | Item Details |
---|---|
2378963 | INTERNAL BATTERY PACK-VIVID-I |
2378963-2 | 2378963-2 |
FL200027 | FL200027 |
FL200068 | FL200068 |
S2378963-3 | S2378963-3 |
S2423267 | S2423267 |